Abstract

Pressure injuries associated with advanced life-support devices represent a significant and growing concern in critical care settings. These device-related injuries, ranging from superficial skin changes to deep tissue damage, can complicate patient recovery, increase morbidity, and prolong hospital stays. This review synthesizes current evidence regarding the epidemiology, pathophysiology, risk factors, clinical features, diagnosis, management, and prevention of pressure injuries induced by devices such as endotracheal tubes, noninvasive ventilation masks, and extracorporeal support apparatus. Emphasis is placed on guideline-based strategies, emerging technologies, and practical approaches for clinicians to minimize the burden of these injuries and optimize patient outcomes.

Introduction

The utilization of advanced life-support devices, including mechanical ventilation interfaces, vascular access catheters, and extracorporeal membrane oxygenation (ECMO) circuits, has become integral to modern critical care. While these devices are lifesaving, their prolonged application is associated with complications, notably device-related pressure injuries (DRPIs). DRPIs not only impact patient comfort and rehabilitation but also pose a risk for secondary infections, increased healthcare costs, and legal implications. Understanding the mechanisms, risk factors, and preventive strategies for DRPIs is essential for multidisciplinary teams in intensive care units (ICUs) and emergency departments.

Epidemiology / Disease Burden

Recent epidemiological studies indicate that DRPIs account for up to 35% of all pressure injuries in ICUs. The prevalence varies based on device type, patient comorbidities, and institutional protocols, with facial injuries from noninvasive ventilation (NIV) masks and nasal injuries from endotracheal tubes being particularly common. Large multicenter cohorts have documented increased rates of DRPIs during pandemics, when device utilization surges and staffing is strained. The economic burden is substantial, as DRPIs are associated with longer ICU stays, increased need for wound care, and higher rates of secondary infections. Importantly, DRPIs are included in hospital-acquired condition metrics, impacting reimbursement and quality ratings.

Pathophysiology

The development of DRPIs is multifactorial, involving mechanical forces such as pressure, friction, and shear at the device-skin interface. Devices exert localized pressure exceeding capillary closing pressure, compromising perfusion and leading to ischemic injury. Moisture from sweat or respiratory secretions, coupled with microclimate changes beneath occlusive devices, exacerbates skin maceration and susceptibility to breakdown. Additionally, rigid device components can induce tissue deformation, especially over bony prominences or in patients with reduced subcutaneous tissue. The inflammatory cascade triggered by ischemia-reperfusion further impairs healing and increases risk of deep tissue injury.

Risk Factors

Several patient- and device-related factors heighten the risk of DRPIs. Intrinsic risk factors include advanced age, impaired mobility, hypoalbuminemia, peripheral vascular disease, and diabetes mellitus. Critically ill patients requiring vasopressor support or prolonged sedation are especially vulnerable. Device-specific risk factors include inappropriate sizing, improper positioning, and lack of routine repositioning. High device-tissue interface pressures, especially over the nasal bridge, occiput, or heels, are implicated in early tissue compromise. Inadequate monitoring and the use of non-breathable materials also significantly increase risk.

Clinical Features

DRPIs typically present as erythema, induration, or ulceration at the site of device contact. Early stages may show non-blanchable redness or blistering, progressing to full-thickness necrosis or exposure of underlying structures if unrecognized. Distinct patterns are associated with specific devices: nasal bridge ulcerations from NIV masks, tracheal stoma breakdown from tracheostomy tubes, or limb injuries from intra-arterial lines. Pain is often underreported due to sedation, underscoring the need for vigilant inspection. Secondary infection, delayed wound healing, and scar formation are common complications.

Diagnosis

Diagnosis of DRPIs relies on thorough clinical assessment, with emphasis on early detection through regular skin and mucosal examinations. Staging follows international guidelines, evaluating depth and extent of tissue involvement. Adjunctive tools such as high-frequency ultrasound or thermography may assist in detecting subclinical injuries. Differential diagnosis includes device-related dermatitis, allergic reactions, and infectious ulcers. Documentation and serial monitoring are crucial for guiding management and evaluating preventive interventions.

Treatment & Management

Management of DRPIs mandates a multidisciplinary approach. Immediate interventions include offloading the affected area, optimizing device fit, and rotating devices where feasible. Wound care should follow evidence-based protocols, employing dressings that maintain moisture balance and protect from secondary trauma. Debridement may be necessary for necrotic tissue, and topical antimicrobials are indicated for infected wounds. Analgesia and nutritional support are essential adjuncts. For severe injuries, plastic surgery consultation or advanced wound therapies such as negative pressure wound therapy may be warranted. Education of healthcare staff and family members is vital for ongoing prevention.

Recent Advances / Emerging Therapies

Innovations in device design, such as the use of softer materials, pressure-distributing cushions, and 3D-printed custom interfaces, are reducing DRPI incidence. Smart sensors that monitor pressure and microclimate dynamics in real-time are being integrated into ICU practice. Hydrocolloid and silicone adhesive dressings applied prophylactically to high-risk areas show promise in randomized trials. Education programs and electronic alert systems have demonstrated efficacy in improving compliance with repositioning protocols. Research into biomarker-driven risk stratification and regenerative therapies for chronic wounds is ongoing.

Guideline Recommendations

International guidelines from organizations such as the National Pressure Injury Advisory Panel (NPIAP) and European Pressure Ulcer Advisory Panel (EPUAP) emphasize routine device assessment, individualized risk stratification, and early preventive interventions. Recommendations include proper device sizing, frequent repositioning, use of protective dressings, and meticulous skin inspection. Institutions are encouraged to implement standardized protocols and multidisciplinary quality improvement initiatives. Ongoing staff education, audit, and feedback loops are integral to sustaining reductions in DRPI rates.

Conclusion

Pressure injuries from advanced life-support devices are a preventable yet persistent challenge in critical care. Awareness of their epidemiology, mechanisms, and risk factors enables timely recognition and intervention. Adherence to guideline-based prevention strategies, coupled with adoption of emerging technologies, can substantially mitigate DRPI incidence and improve outcomes for vulnerable patients. Continued research and innovation remain essential in the evolving landscape of device-related complications.