Abstract

Complex pelvic ring injuries are high-energy musculoskeletal lesions associated with substantial hemorrhage, visceral trauma, neurologic impairment, infection, malunion, and long-term functional disability. Accurate restoration of pelvic alignment and stable fixation are essential, yet conventional two-dimensional fluoroscopy may provide incomplete visualization of overlapping bony structures and can obscure residual displacement, screw malposition, or joint incongruity. Intraoperative three-dimensional fluoroscopy, commonly performed with a mobile cone-beam computed tomography system, provides multiplanar and volumetric imaging during surgery. This technology can improve assessment of fracture reduction, facilitate percutaneous fixation, and permit immediate correction of implant-related problems before wound closure. Its clinical value is greatest in anatomically complex injuries involving the sacroiliac joint, posterior pelvic ring, acetabular margins, pubic symphysis, or multiple pelvic compartments. Successful application requires appropriate patient selection, meticulous positioning, radiation-safety protocols, coordination between surgeons and imaging personnel, and a clear understanding of the limitations of intraoperative image quality. Current evidence supports improved detection of suboptimal reduction and screw penetration, although effects on complications, reoperation, and long-term patient-reported outcomes remain heterogeneous. Intraoperative three-dimensional fluoroscopy should therefore be viewed as an adjunct to, rather than a replacement for, sound pelvic trauma principles, preoperative computed tomography, and postoperative clinical assessment.

Introduction

Pelvic ring injuries represent a spectrum ranging from stable, minimally displaced fractures to mechanically unstable disruptions involving the anterior and posterior pelvic complexes. High-energy mechanisms such as motor-vehicle collisions, falls from height, industrial trauma, and crush injuries frequently produce complex patterns with rotational and vertical instability. Management is challenging because the pelvis is a three-dimensional osseous ring situated near major vessels, pelvic viscera, lumbosacral nerve roots, and weight-bearing joints. Small residual deformities may alter load transfer across the sacroiliac joints and hip, while inaccurate screw placement may injure neural or vascular structures.

Preoperative multidetector computed tomography remains central to injury characterization and operative planning. During fixation, however, surgeons must translate axial and reconstructed images into intraoperative anatomy that may be distorted by traction, positioning, reduction maneuvers, implants, and radiolucent operating tables. Standard anteroposterior, inlet, outlet, and oblique fluoroscopic views are indispensable but may be limited by bowel gas, obesity, metallic instrumentation, sacral dysmorphism, and overlapping pelvic contours. Three-dimensional fluoroscopy addresses some of these limitations by generating a volumetric dataset after reduction and fixation. The resulting information may support safer, more precise, and more reproducible pelvic reconstruction.

Epidemiology / Disease Burden

Pelvic ring injuries are relatively uncommon compared with isolated long-bone fractures, but they carry disproportionate morbidity and resource requirements. Severe disruptions are frequently associated with polytrauma, traumatic brain injury, thoracic injury, abdominal injury, genitourinary trauma, and extremity fractures. Hemodynamic instability may arise from arterial bleeding, venous plexus injury, cancellous bone surfaces, or associated visceral damage. Even after acute survival, patients may experience chronic pelvic pain, gait disturbance, sexual dysfunction, urinary symptoms, neurologic deficits, post-traumatic arthritis, and inability to return to work.

The burden is not limited to mortality. Inadequate reduction of the posterior ring can produce altered spinopelvic mechanics and persistent asymmetry. Symptomatic implant malposition may require revision, and nonunion or malunion can necessitate complex reconstructive surgery. These consequences explain why intraoperative quality control is clinically important, particularly in injuries where conventional radiographs do not reliably demonstrate the true three-dimensional relationship of the fracture fragments and implants.

Pathophysiology

Pelvic ring instability results from disruption of one or more structural components that normally transmit axial and rotational forces between the spine and lower limbs. External rotation injuries may open the anterior ring and stretch or rupture the anterior sacroiliac ligaments, whereas lateral compression injuries produce internal rotation, sacral impaction, and fractures of the pubic rami. Vertical shear injuries can disrupt the entire hemipelvis, including the sacroiliac complex, pelvic floor, and anterior ring, allowing superior migration.

Posterior ring injury is the principal determinant of mechanical instability. The sacroiliac joint, sacral foramina, and transforaminal sacral corridors have substantial anatomical variation. Sacral dysmorphism can narrow safe pathways for iliosacral or transiliac-transsacral screws, and fracture displacement can further distort these corridors. Three-dimensional imaging is particularly relevant because an implant that appears satisfactory on one projection may breach the neural foramina, spinal canal, vascular notch, or adjacent joint on another plane.

Risk Factors

Risk factors for complex pelvic ring injury include high-energy blunt trauma, advanced age with osteoporosis, anticoagulant use, polytrauma, reduced bone quality, and delayed transfer to a specialist trauma center. Patient factors that complicate intraoperative imaging include obesity, abdominal distension, external fixation devices, extensive soft-tissue injury, and inability to tolerate the required supine or prone position. Anatomical factors include sacral dysmorphism, comminution, osteopenia, prior pelvic surgery, distorted landmarks, and concomitant acetabular or spinal fractures.

Procedural risk is increased when the surgical team has limited experience with three-dimensional acquisition, when the imaging arc cannot be adequately positioned, or when image registration is affected by movement between acquisition and interpretation. These risks emphasize the need for preoperative planning, standardized workflows, and direct communication among the orthopedic trauma surgeon, radiographer, anesthesiologist, and nursing team.

Clinical Features

Patients may present with severe pelvic or lower-back pain, inability to stand, limb shortening or malrotation, pelvic instability, perineal bruising, scrotal or labial swelling, hematuria, rectal bleeding, or neurological symptoms. Hemodynamic instability should be assumed to reflect life-threatening hemorrhage until proven otherwise. Examination must include repeated assessment of distal pulses, motor and sensory function, perineal sensation, rectal tone when indicated, and signs of urethral or bladder injury.

Open pelvic injuries require immediate recognition because contamination, soft-tissue devitalization, and infection risk substantially influence treatment. Neurologic deficits may indicate sacral fracture displacement, foraminal compromise, lumbosacral plexus injury, or associated spinal pathology. Clinical examination alone cannot define the mechanical pattern; it must be integrated with imaging and the patient's physiologic condition.

Diagnosis

Initial assessment follows established trauma principles, with simultaneous resuscitation and evaluation for associated injuries. Anteroposterior pelvic radiography may rapidly identify major diastasis, vertical displacement, or gross ring disruption, but computed tomography is generally required for definitive characterization. Thin-slice multiplanar and three-dimensional reconstructions help determine fracture morphology, sacral involvement, posterior displacement, acetabular extension, and the feasibility of percutaneous corridors.

Intraoperative three-dimensional fluoroscopy is obtained after reduction and provisional or definitive fixation. The mobile imaging unit rotates around the patient to acquire a series of projections that are reconstructed into axial, sagittal, coronal, and oblique views. The surgeon can evaluate residual gap, rotational malalignment, implant trajectory, screw length, articular penetration, and posterior ring congruity. When image quality is inadequate because of body habitus, metal artifact, positioning, or field-of-view restrictions, intraoperative computed tomography or postoperative computed tomography may be more appropriate.

Treatment & Management

Management begins with hemorrhage control, pelvic stabilization, correction of coagulopathy, temperature preservation, and treatment of associated injuries. A pelvic binder or temporary external fixation may reduce pelvic volume in selected patterns, while preperitoneal packing, angioembolization, resuscitative endovascular balloon occlusion, or surgical control may be required according to local expertise and injury characteristics. Definitive fixation is planned after physiologic stabilization, although selected injuries require early operative stabilization to support mobilization and reduce ongoing mechanical bleeding.

Operative strategy depends on the instability pattern, soft-tissue condition, fracture morphology, and patient physiology. Posterior fixation may involve percutaneous iliosacral screws, transsacral screws, triangular osteosynthesis, lumbopelvic fixation, or open reduction with plating. Anterior ring reconstruction may use plates, screws, external fixation, or combined techniques. Intraoperative three-dimensional imaging is especially useful after posterior screw insertion, when the risk of unnoticed breach is clinically meaningful and conventional projections may be difficult to interpret.

A practical workflow includes reviewing preoperative computed tomography, positioning the patient to permit unobstructed imaging, obtaining baseline fluoroscopic views, performing reduction under traction or direct manipulation, inserting provisional fixation, and acquiring a three-dimensional dataset. The images should be reviewed systematically rather than impressionistically. If malreduction or implant malposition is identified, correction should occur before final closure. The acquisition should then be repeated when clinically necessary. Radiation exposure, operative time, sterile-field constraints, and the possibility of incomplete visualization must be considered in every case.

Recent Advances / Emerging Therapies

Recent developments include improved mobile cone-beam systems, enhanced metal-artifact reduction, automated image reconstruction, navigation-compatible platforms, and integration with computer-assisted pelvic surgery. Three-dimensional fluoroscopy can be combined with fluoroscopic navigation, electromagnetic tracking, or robotic assistance to improve targeting of narrow osseous corridors. Patient-specific planning based on preoperative computed tomography may help define safe screw trajectories in dysmorphic sacra and comminuted fractures.

Artificial intelligence and automated segmentation may eventually support rapid recognition of malalignment, cortical breach, or inadequate screw purchase, but these applications require external validation and careful oversight. Emerging fixation methods, including stronger percutaneous implants, expandable devices, and minimally invasive spinopelvic constructs, may expand treatment options for osteoporotic or highly unstable injuries. Nevertheless, technology cannot compensate for inadequate reduction, poor soft-tissue management, or failure to recognize ongoing hemorrhage.

Guideline Recommendations

Contemporary trauma principles recommend immediate stabilization of the physiologically unstable patient, multidisciplinary management of associated injuries, and definitive fixation tailored to the mechanical pattern. Preoperative computed tomography should guide reduction strategy and implant selection. Intraoperative imaging should be used to confirm alignment and hardware position whenever anatomy is complex, visualization is limited, or percutaneous fixation is performed near neural, vascular, or articular structures.

Three-dimensional fluoroscopy should be incorporated within a standardized quality-assurance protocol. The team should establish acceptable reduction criteria before surgery, verify that the imaging system covers the complete region of interest, minimize radiation through appropriate technique, and document any correction prompted by intraoperative findings. Postoperative computed tomography remains appropriate when intraoperative images are inconclusive, when symptoms suggest implant-related complications, or when the injury pattern exceeds the capability of the available system. Early thromboprophylaxis, infection prevention, mobilization when mechanically safe, and coordinated rehabilitation remain essential components of care.

Conclusion

Intraoperative three-dimensional fluoroscopy provides valuable volumetric confirmation during fixation of complex pelvic ring injuries. By revealing residual displacement and implant malposition that may be occult on standard projections, it can improve intraoperative decision-making and reduce the need for avoidable revision procedures. Its greatest benefit is achieved in posterior ring injuries, percutaneous screw fixation, anatomically dysmorphic sacra, and cases with difficult fluoroscopic visualization. The technology should be integrated with trauma resuscitation, high-quality computed tomography planning, meticulous reduction technique, radiation stewardship, and postoperative clinical surveillance. Although further prospective research is needed to define its effect on long-term outcomes and cost-effectiveness, current clinical practice supports its selective use as an important adjunct in modern pelvic trauma surgery.